Acute Particulate Evaluation
ASTM and ISO regulations require acute phase particulate testing of medical devices destined for human vasculature in order to assess safety, risk, and efficacy during tracking, deployment, and withdrawal.
We utilize a temperature-controlled positive-pressure flow loop with customizable deployment platform to simulate the vascular pathway your devices will travel for deployment. In-line particle sensors provide a time course of particle sizes and counts throughout the sample run. Collection of shed particles on the integrated filter membrane allow for subsequent SEM/EDX and/or FTIR analysis. This approach allows manufacturers to know the precise particle contribution of their devices and deployment accessories.
In collaboration with Dynatek Labs, we utilize patented Acute Particulate Testers for acute applications. Acute Particulate Testing of vascular devices such as stents, stent-grafts, balloons, occluders, and delivery systems can include:
- Particulate Matter Evaluation during Deployment and Withdrawal
- Coating Integrity Inspection
- Evaluation of Particulate during Simulated Balloon Expansion
As recommended by the FDA, the aims are to “demonstrate that the delivery catheter can safely and reliably deliver the stent to the intended location and that the stent is not adversely affected by the delivery catheter, both during deployment and withdrawal.” Together with Dynatek, we can help you to design, rationalize, and implement your testing to comply with the typical standards and guidance documents. The following standards and regulations are followed (where applicable):
- ASTM F2394-07 (2017) – Standard Guide for Measuring Securement of Balloon Expandable Vascular Stent Mounted on Delivery System
- ISO 25539-2:2012 – Cardiovascular Implants – Endovascular Devices – Part 2: Vascular stents
- FDA Guidance for Industry and FDA Staff – Non-Clinical Engineering Tests and Recommended Labeling for Intravascular Stents and Associated Delivery Systems, April 18, 2010
- FDA Guidance – Class II Special Controls Guidance Document for Certain Percutaneous Transluminal Angioplasty (PTCA) Catheters
- ASTM F2743-11 – Coating Inspection and Acute Particulate Characterization of Coated Drug-Eluting Vascular Stent Systems
- AAMI TIR42:2010 – Evaluation of Particulates Associated with Vascular Medical Devices
- ASTM WK46148 – Standard Guide for Acute InVitro Evaluation of Drug Coated Balloons
- ISO 12417-1:2015 – Cardiovascular Implants and Extracorporeal Systems — Vascular device-drug combination products
- ISO/TS 17137:2014 – Cardiovascular implants and extracorporeal systems — Cardiovascular absorbable implants
- ASTM F3036-13 – Standard Guide for Testing Absorbable Stents
- ASTM WK60510 – New Test Method for Simulated use testing of neurointerventional device in tortuous vasculature
- ASTM WK60511 – New Test Method for Particle evaluation and characterization for neurointerventional devices
For more information on testing and evaluation of your vascular devices, please feel free to contact us.